MEDIUM VOLTAGE

Standard IEC 60502-2

Cu or Al / XLPE / Cu / PVC or PE

APPLICATION Cable for power distribution and power supply stations used in Utility and Industrial applications, for rated voltages up to 18/30kV. Suitable for fixed installations, indoor or outdoor, in open air on cable trays, or un¬derground in ducts or directly buried. CABLE DESIGNATION Cu / XLPE / Cu Tape screen / PVC or PE: Cu […]
More Details

Flame retardant, Halogen free

Cu or Al / XLPE / Cu / PO

Cu or Al / XLPE / Cu / PO Flame retardant, Halogen free Construction and test standards HD 620S2 , IEC 60502-2 Rated voltage U0 / U(Um) 3,6/6 (7,2)KV . 6/10 (12) KV , 8,7/15(17,5) KV . 12/20(24) KV . 18/30(36) KV Standard cross-section of wire screen 16 . 25 . 30 . 35 Test […]
More Details

Aluminium screen

Cu or Al / XLPE / Al / PE

Cu or Al / XLPE / Al / PE Construction and test standards IEC 60228 , TEC 60502 Rated voltage U0 / U(Um) 3,6/6 (7,2)KV . 6/10 (12) KV . 8,7/15 (17,5) KV . 12/20(24) KV Test Voltage 3,5 x Uo Conductor maximum operating temperature 90 degree centigrade Maximum short-circuit temperature 250 degree centigrade Minimum […]
More Details

Reinforced transversal watertightness

Cu or Al / XLPE / Cu / Al / PE

Cu or Al / XLPE / Cu / Al / PE Construction and test standards IEC 60228 , IEC 60502-2 Rated voltage U0 / U(Um) 3,6/6 (7,2)KV . 6/10 (12) KV . 8,7/15 (7,15) KV . 12/20 (24) KV . 18/30 (36) KV Standard cross-section of wire screen 16 . 25 . 30 . 35 […]
More Details

Standard IEC 60502-2

Cu or Al / EPR / Cu / PVC or PE

Voltage UV   MV condoctor – Cross Section Diameter over Insulation Approx outer Diameter Approx weight XHIO Current caraying capasity in air (A) Current caraying capasity Burried (A) Condoctor max short circuit current t=1s cond DC resistance @ 20c Inductance mH\km Capacitance Pf/Km Copper conductor 3.6/6 7.2 25 13.0 20.0 655 157 160 3.6 0.7270 […]
More Details

Standard IEC 60502-2

Cu or Al / XLPE / Cu / ATA or AWA / PVC or PE

Voltage u/u UM kv conducter cross section (mm2) Diameter over insulation (mm) Approx Outer Diameter (mm) Approx weight XH10A1 (kg/km) Current carraying capacity in air capacity in bound cond. max short circuit current conducter DC resistance @20 c Inductance mh/am Capacitance uf/am Copper conductor 3.6/6 7.2 25 13.0 25.5 960 164 164 3.6 0.7270 0.44 […]
More Details

Without messenger

Cu or Al / XLPE / Cu / PVC or PE

Cu or Al / XLPE / Cu / PVC or PE Construction and test standards IEC 60228 , TEC 60502 Rated voltage U0 / U(Um) 3,6/6 (7,2)KV . 6/10 (12) KV Standard cross-section of wire screen 16 . 25 . 30 . 35 Conductor maximum operating temperature 90 degree centigrade Maximum short-circuit temperature 250 degree […]
More Details

With messenger

Al / XLPE / Cu / PVC or PE

Al / XLPE / Cu / PVC or PE Construction and test standards IEC 60228 , TEC 60502 Rated voltage U0 / U(Um) 3,6/6 (7,2)KV . 6/10 (12) KV Standard cross-section of wire screen 16 . 25 . 30 . 35 Conductor maximum operating temperature 90 degree centigrade Maximum short-circuit temperature 250 degree centigrade Minimum […]
More Details

Standard IEC 60502-2

Cu or Al / XLPE / Cu / PVC or PE

Voltage u/u UM kv conducter cross section (mm2) Diameter over insulation (mm) Approx Outer Diameter (mm) Approx weight XH10A1 (kg/km) Current carraying capacity in air capacity in bound cond. max short circuit current conducter DC resistance @20 c Inductance mh/am Capacitance uf/am Copper conductor 3.6/6 7.2 25 13.0 39.5 2 395 142 148 3.6 0.7270 […]
More Details

Standard IEC 60502-2

Cu or Al / XLPE / Cu / STA or SWA / PVC or PE

Untitled Document Voltage u/u UM kv conducter cross section (mm2) Diameter over insulation (mm) Approx Outer Diameter (mm) Approx weight XH10A1 (kg/km) Current carraying capacity in air capacity in bound Cond. max short circuit current Conducter DC resistance @20 c Inductance mh/am Capacitance uf/am Copper conductor 3.6/6 7.2 25 13.0 44.5 3 320 143 148 […]
More Details